- Amer S. Al-Khafagi1, Fatima O. Nasser2 & Omar Ahmed Muwafaq Safauldeen3
- DOI: 10.5281/zenodo.23832219
- GAS Journal of Clinical Medicine and Medical Research (GASJCMMR)
In
this work a theoretical and semi-empirical analysis of the mass stopping power
of human blood in the electron kinetic energy interval of 110–270 MeV and of
liquid water in the same interval has been carried out. The theoretical
calculations were done by the relativistic Bethe–Bloch equations and a
three-parameter semi-empirical equation, which is a function of the electron
kinetic energy (T), was obtained by fitting a non-linear curve in MATLAB. The
results have been compared with reference values obtained from the ESTAR
database of the National Institute of Standards and Technology (NIST) to check
the accuracy and reliability of the proposed models. The following statistical
parameters were used for the assessment: Pearson’s correlation coefficient, the
root mean square error (RMSE), the mean absolute error (MAE) and the standard
deviation of paired differences. The results indicated that the semi-empirical
prediction results were in excellent agreement with the ESTAR reference data:
for liquid water, 99.99% accuracy was reported and for human blood, 98.80%
accuracy was reported. The values of RMSE were 0.0576 and 8.1790 MeV·cm²/g,
respectively. The theoretical and semi-empirical results also showed very close
linear correlation between them, with the Pearson’s correlation coefficient
being 0.999719 for water and 0.999769 for blood, but it was found that there
are significant differences between their numerical values. These results show
that a very high correlation does not necessarily mean numerical agreement and
the need to correctly describe the stopping power contributions that depend on
energy at high electron energy. The proposed semi-empirical equation was in
good agreement with the ESTAR reference data and may be useful for modelling
the electron mass stopping power in biological materials and may be also
helpful in further radiation dosimetry studies.
Keywords: Electron kinetic energy; Electron mass stopping power; Human blood; Liquid water; Semi-empirical equation; Bethe–Bloch equation; ESTAR database.